DC-Micromotors
2642W015CXR
Graphite Commutation
Part No.: 2642.01179
Key Features
| Nominal voltage: | UN | 15 V |
|---|---|---|
| Rated torque up to: | MN | 26.3 mNm |
| No-load speed up to: | n0 | 5770 min⁻¹ |
| Stall torque up to: | MH | 145 mNm |
| Diameter: | Ø | 26 mm |
| Length: | L | 42 mm |
Advantages
- Highly dynamic performance due to a low rotor inertia
- Shockproof all-steel housing with corrosion-resistant coating
- Powerful rare-earth magnet
- Wide operating temperature range: -30 °C to +100 °C (optional -55 °C)
- Durable graphite commutation
- No cogging
- Very high power density
| Nominal voltage: | UN | 15 V |
|---|---|---|
| Terminal resistance: | R | 2.38 Ω |
| Efficiency, max.: | ηmax. | 77 % |
| No-load speed: | n0 | 5770 min⁻¹ |
| No-load current: | I0 | 0.0717 A |
| Stall torque: | MH | 145 mNm |
| Friction torque: | MR | 1.7 mNm |
| Speed constant: | kn | 396 min⁻¹/V |
| Back-EMF constant: | kE | 2.53 mV/min⁻¹ |
| Torque constant: | kM | 24.1 mNm/A |
| Current constant: | kI | 0.041 A/mNm |
| Slope of n-M curve: | Δn/ΔM | 39.1 min⁻¹/mNm |
| Rotor inductance: | L | 228 µH |
| Mechanical time constant: | τm | 4.5 ms |
| Rotor inertia: | J | 12 gcm² |
| Angular acceleration: | αmax. | 138 ·10³rad/s² |
| Thermal resistance: | Rth1/Rth2 | 4.9 / 16 K/W |
| Thermal time constant: | τw1/τw2 | 24 / 749.3 s |
| Operating temperature range: | -30 ... 100 °C | |
| Winding temperature, max.: | 125 °C | |
| Housing material: | steel, zinc galvanized and passivated | |
| Mass: | 114 g | |
| Direction of rotation: | clockwise, viewed from the front face | |
| Speed up to: | nmax. | 7000 min⁻¹ |
| Number of pole pairs: | 1 | |
| Magnet material: | NdFeB |
Operating Area of motor
The diagram indicates the recommended speed in relation to the available torque at the output shaft for a given ambient temperature of 22°C.
The diagram shows the motor in a completely insulated as well as thermally coupled condition (Rth2 50% reduced).
The nominal voltage (UN) curve shows the operating point at nominal voltage in the insulated and thermally coupled condition. Any points of operation above the curve at nominal voltage will require a higher operating voltage. Any points below the nominal voltage curve will require less voltage.
Motor Characteristic curves
Download
3D-CAD Files
Datasheet
Technical Information