Skip to main content Skip to search Skip to main navigation
Nominal voltage: UN 12 V
Terminal resistance, phase-phase: R 3.5 Ω
Efficiency, max.: ηmax. 74 %
No-load speed: n0 6700 min⁻¹
No-load current: I0 0.072 A
Stall torque: MH 58.7 mNm
Friction torque, static: C0 0.46 mNm
Friction torque, dynamic: CV 1.1 ·10⁻⁴ mNm/min⁻¹
Speed constant: kn 562 min⁻¹/V
Back-EMF constant: kE 1.78 mV/min⁻¹
Torque constant: kM 17 mNm/A
Current constant: kI 0.059 A/mNm
Slope of n-M curve: Δn/ΔM 114 min⁻¹/mNm
Terminal inductance, phase-phase: L 115 µH
Mechanical time constant: τm 6.1 ms
Rotor inertia: J 5.1 gcm²
Angular acceleration: αmax. 115 ·10³rad/s²
Thermal resistance: Rth1/Rth2 3.9 / 18.8 K/W
Thermal time constant: τw1/τw2 7.9 / 520 s
Operating temperature range: -40 ... 100 °C
Winding temperature, max.: 125 °C
Housing material: stainless steel
Mass: 65 g
Direction of rotation: electronically reversible
Speed up to: nmax. 29000 min⁻¹
Number of pole pairs: 2
Hall sensors: digital
Magnet material: NdFeB

Operating Area of motor

2232S012BX4
The diagram indicates the recommended speed in relation to the available torque at the output shaft for a given ambient temperature of 22°C.
The diagram shows the motor in a completely insulated as well as thermally coupled condition (Rth2 50% reduced).
The nominal voltage (UN) curve shows the operating point at nominal voltage in the insulated and thermally coupled condition. Any points of operation above the curve at nominal voltage will require a higher operating voltage. Any points below the nominal voltage curve will require less voltage.

Motor Characteristic curves

2232S012BX4
Serie 2232 ... BX4

Download

3D-CAD Files
Technical Information

Application note

AN 162 - Analog Hall Sensors
AN 163 - Digital Hall Sensors
AN 183 - Equivalent DC-current in FAULHABER SC and MC
AN 190 - Selection of a third-party motor driver
AN 200 - SIN-COS interface and temperature sensor